DxH 900

Hematology Analyzer

Trusted Quality. Trusted Results.
The DxH 900 hematology analyzer delivers accurate and high-confidence results on the first run. With its best-in-class hematology technology, this automated analyzer minimizes slide reviews, maximizes laboratory staff time, and provides significant cost savings. The DxH 900 offers scalable, customized solutions to address the hematology testing needs of high-volume labs.

Quality That Counts
Trust your results—the first time—with high-quality hematology analyzers that deliver precise, accurate results and advanced cellular insights.

  • Achieve superior RBC, PLT and WBC differentials through near native-state cellular characterization
  • Deliver high-confidence results on the first run—minimizing reruns and reflex tests
  • Improve slide interpretation with intelligent technology that helps optimize smearing, ensuring consistent slide quality

Productivity That Liberates
Free up your busy laboratory’s hematology team and empower your staff to focus on samples and tasks that truly need attention

  • Simplify workload planning with predictable hematology workflows that let you save time for the unexpected 
  • Optimize your limited resources with reliable flagging

Savings That Empower
Tap into powerful savings to help your lab devote time, budget, and resources where they are needed most

  • Streamline QA/QC processes through customizable, automated technology with daily reminders and remote support
  • Save time, reduce costs, and optimize hematology instrument usage with fewer reflex tests 
    o  Reduce hematology reagent use and associated costs
    o  Reallocate up to 200 minutes of daily run-time previously spent on reflex testing1
    o  Reduce overhead costs like electricity and maintenance
     

Technical Specifications

Methodology

Enhanced Coulter Principle, VCS 360 with DataFusion

Parameters

CBC: WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW, RDW-SD, PLT, MPV

Differential: NE, LY, MO, EO, BA, NRBC, NE#, LY#, MO#, EO#, BA#, NRBC #, MDW (when enabled)

Retic: RET, RET#, MRV, IRF

Body Fluids (Cerebrospinal, Serous, or Synovial): RBC, TNC

Throughput (tests per hour)

Up to 100 samples/hour

Sample Volumes

165 μL aspiration volume; 0.5 ml dead volume. Predilute: 50 μL whole blood into 200 μL of diluent

Analytical Measuring Ranges2

Whole Blood (CBC)

Parameters

Units

Analytical Measuring Range

WBC

x103 cells/μL

0.050–400.000

RBC

x106 cells/μL

0.005–8.500

HGB

g/dL

0.10–25.50

MCV

fL

50.00–150.00

RDW

%

10.00–40.00

RDW-SD

fL

15.00–150.00

PLT

x103 cells/μL

3.0–3000.0

MPV

fL

5.00–25.00

Body Fluids

TNC

cells/mm3

20–89,000

RBC

cells/mm3

1,000–6,200,000

Data Management

Up to 50,000 patient results with histograms, scatter plots, and demographics

100,000 patient results with graphics for power computer

Quality Assurance

QC with Levy-Jennings graph; XB/XM for moving averages, daily check, intelligent quality monitoring, MRV, IRF, customizable calibration and QC reminders and alerts, auto export of QC

Acoustic Noise Level

≤ 60 dBa

Radio Frequency and Interference Immunity

Meet the product level standards EN 61326-1 (Electrical Equipment for Measurement, Control, and Laboratory Use—EMC Requirements), and EN 61326-2-6 (Part 2, Specific Requirements for In-Vitro Diagnostic Devices)

Power Consumption

DxH 900 SPM: 520 W (1775 BTU/hour), Monitor: 35 W (120 BTU/hour), DxH Power Computer: 160 W (546 BTU/hour)

Dimensions and weight3

Width

Height

Depth

Weight

76.2 cm (30 in.)

176.53 cm (69.5 in.), with cover closed

199.39 cm (78.5 in.), with cover open

83.82 cm (33 in.), including the removable back panel

80 cm (31.5 in.), excluding the removable back panel

~292.11 kg (644 lbs.),
including monitor & computer

~287.12 kg (633 lbs.),
excluding computer

Additional Clearance

15.2 cm (6.0 in.) per side of instrument for troubleshooting; 3.8 cm (1.5 in.) behind instrument for sufficient cooling

 

Maintenance and Troubleshooting

Service

New Preventative Maintenance (PM) schedule with customer care visits

Support 

Onboard IFU and Instructional Videos, Automated QC and calibration reminders, PROService 

Analyzer Downtime

Minimum of 30 minutes in cleaner every 24 hours with automatic daily checks

 

Research Use Only Parameters

Available RUO Parameters4

BFM, BFM#, BFP, EGC, EGC#, HLR, HLR#, LHD, MAF, MSCV, PCT, PDW, RDWR, RDWR-SD, RSF, UGC, UGC#, UWROP, WDOP, WNOP, WROP, CPD (refer to reference 4 for additional RUO parameters)

Research Use Only. Not for use in In Vitro Diagnostic procedures.

2. DxH 900 IFU (PN C06947.AD)
3. DxH 900 ReadMe (PN C53971.AB)
4. DxH 900 RUO Addendum

WhatsApp Chat