DxI 9000

Access Immunoassay System

We created time for you to focus on what matters most.
The award-winning DxI 9000 Analyzer sets a new standard with first-of-its-kind high sensitivity immunoassay testing capabilities for the core labs. Featuring meaningful innovations that amplify your impact, liberate you from the laborious, and power your performance across your health system, this high-throughput immunoassay analyzer takes diagnostics to the next level.

Expect the High Sensitivity and Precision Your Lab Needs

Six Sigma quality performance for Immunoassay enabling the laboratory to deliver high-quality results with greater sensitivity, even at lower sample volumes and in high throughput settings.

Don’t choose between speed and sensitivity.

Improved Sensitivity
Chemiluminescent Lumi-Phos PRO3 substrate delivers full glow in <1 minute, improved signal to noise ratio, and minimizes interference from endogenous ALP.

Improved Detection
Patented luminometer exhibits an expanded linear range to optimize signal detection at both low and high levels of light using multiple measurement methods.

Enhanced Precision
Dedicated sample pipettor and new disposable tips delivers sample to all 4 build stations reducing the potential of carryover; capable of delivering down to 2 μL of sample with ≤ 2% CV

 

Create time to focus on what matters most.

The DxI 9000 Access Immunoassay Analyzer sets a new standard for today’s busy labs. With meaningful innovations that amplify your impact, liberate you from the laborious, and power your performance across your health system, we’re taking diagnostics to the next level.

Review these instrument specifications to set up your lab for success.

Main Specifications

Analytical method

  • Chemiluminescent detector: luminometer

Barcoded reagents

  • Automatic tracking of:
    • Number of tests
    • Available tests
    • Expiration date
    • Lot number
    • Calibration expiration and printouts

Calibration

  • Calibration curve stability up to 64 days (assay dependent)
  • Calibration curves and parameters displayed on screen

Communication modes

  • Unidirectional, bi-directional, bi-directional with true host query
  • Both RS-232 and LAN connections are supported

Compartment temperatures

  • Incubator and wash/read wheel: 98.6°F (37°C)
  • Sample wheel: 40.1°F to 57.2°F (4.5°C to 14°C)
  • Reagent compartment: 39.2°F to 50°F (4°C to 10°C)

Immunoassay menu capacity

  • >50 preprogrammed, barcoded immunoassay methods currently available

Measurement principles

  • Acridan based chemiluminescent Lumi-Phos PRO

Sample container sizes

  • Ability to accommodate any tube between 12–16mm in diameter and 75–100mm in height
  • Sample cups:
    • 0.5 mL
    • 2.0 mL
    • 3.0 mL
  • 2.0 mL insert cups
  • Pediatric insert
  • Auto aliquot tube

Sample management/capacity

  • 140 sample tubes (20 racks of 7 tubes), unique continuous loading feature
  • Primary tube released after aliquot is made (approx. 1 minute) 300 aliquots (≤200 μL) per hour
  • Capable of automation connection
  • Barcode symbology:
    • Ability to read 1-D and 2-D symbologies with camera technology.
  • Sample volume:
    • 2-100 μL (assay dependent)
    • 500 μL in aliquot vessel, maximum (including any potential reflex tests)
  • Sample and reagent pipettor obstruction detection

Sample types (assay dependent, partial list)

  • Serum
  • Plasma
  • Urine
  • Amniotic fluid
  • Whole blood

Reagent storage capacity

  • 50 reagent packs:
    • System menu can be configured to match laboratory testing patterns (ability to load one pack of 50 different assays or 50 packs of one assay)
  • Automatic disposal of empty packs

Throughput

  • Up to 450 tests/hr maximum (one-step assays)

Installation Requirements

Dimensions and weight

  • Analyzer:
    • Weight: 1,842 lbs (836 kg)
    • Length: 79 in (200 cm)
    • Height: 63 in (159 cm)
    • Depth: 41 in (104 cm)
  • Clearance Requirements:
    • Clearance around the analyzer for ventilation
    • Rear: Minimum of 20 in (50 cm)
  • Clearance around the analyzer for service:
    • Rear: Minimum of 20 in (50 cm)
    • Left: 0 in (0 cm)
    • Right: Minimum of 15 in (38.1 cm)
    • Top: Minimum of 22 in (56 cm)
    • Front: Minimum of 50 in (127 cm)

Waste requirements

  • Solid waste (Tips, RVs, Reagent Packs) collected in waste container. (No manual removal required for operation)
  • Tip trays, substrate bottles and caps stored separately for recycling capability purposes
  • Floor drain only
  • Drain Location:
    • Maximum distance 33 ft (10 m) from the system
    • Maximum height 4 ft (1.5 m) from the floor

Power and environmental requirements

  • Power Supply: 200-240 VAC at 1600 VA, at either 50 Hz or 60 Hz, single phase
  • Frequency: 47–63 Hz
  • Power: No greater than 2,700 W
  • Computer:
    • CPU Intel Core i7-6700 processor
    • Memory: 2 x 16GB DDR4-2133
    • Storage: 2 x 240GB SSD
    • Operating system: Windows 10
    • External communication types
  • RS232 serial interface:
    • Ethernet: LAN using TCP/IP
  • Monitor:
    • Touchscreen display: 21.5 in diagonal TFT LCD with projected capacitive touch
  • Interface:
    • Pixels: 1920 x 1080 RGB
  • Heat output: 4,231 BTU/hr
  • Ambient operating environment
    • Ambient temperature: 64°F to 86°F (18°C to 30°C)
    • Humidity: 20% to 80%
  • Altitude: 7,500 ft (2.286 km)
  • Noise Level: <60 dB at 1000Hz
  • Water: No water requirement
  • Drain Volume: >1.85 gal/hr (>7 L/hr)
WhatsApp Chat